4.7 Article

Detection of reverse osmosis membrane fouling with silica, bovine serum albumin and their mixture using in-situ electrical impedance spectroscopy

期刊

JOURNAL OF MEMBRANE SCIENCE
卷 443, 期 -, 页码 45-53

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.memsci.2013.04.047

关键词

RO membrane; Fouling; Electrical impedance spectroscopy; Silica; BSA

资金

  1. Environment and Water Industry Development Council (EWI) Singapore under Incentive for Research and Innovation Scheme [0901-IRIS-03-06]

向作者/读者索取更多资源

Monitoring the 'state of the process' is particularly useful in fouling control in the reverse osmosis (RO) industry. In this paper, a novel non-invasive method to monitor the fouling process of single and binary foulants on the RO membrane has been studied; that of electrical impedance spectroscopy (EIS). A typical RO crossflow cell was equipped with electrodes to allow in-situ EIS measurement of the fouling process during RO filtration. The EIS signals were converted to Nyquist plots of the negative imaginary impedance versus the real impedance, and used as a convenient means for characterization of fouling. Different forms of the Nyquist plot were obtained for different types of foulant. Also a significant shift in the Nyquist plots for silica, BSA and their mixtures occurred corresponding to the buildup of a foulant layer on the membrane surface. During the early stages of fouling, the Nyquist plots shifted noticeably while the transmembrane pressure (TMP) showed negligible increase. If EIS could perform on-line in plant operation, it could be a sensitive monitoring tool to detect early fouling in RO membrane filtration. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据