4.7 Article

Micellar enhanced ultrafiltration of phenol in synthetic wastewater using polysulfone spiral membrane

期刊

JOURNAL OF MEMBRANE SCIENCE
卷 310, 期 1-2, 页码 149-160

出版社

ELSEVIER
DOI: 10.1016/j.memsci.2007.10.046

关键词

micellar enhanced ultrafiltration; phenol; CPC; spiral membrane; retentate

向作者/读者索取更多资源

The micellar enhanced ultrafiltration (MEUF) of phenol in synthetic wastewater using two polysulfone spiral membranes of 6- and 10-kDa molecule weight cut-off (MWCO) and cetylpyridinium chloride (CPC) as cationic surfactant was studied. The effects on the permeate flux, permeate and retentate concentrations of phenol and CPC of various factors in the practical application of MEUF were studied, including surfactant and phenol concentrations, retentate flux, operating pressure, temperature and electrolyte. It was found that these two membranes could adsorb free phenol so the concentration of permeate phenol was lower than that of free phenol. The retentate phenol concentration kept increasing, then decreased slightly with the increase of the feed CPC concentration. Retentate flux and temperature had great effect on the performance of MEUF, and operating pressure did not. The addition of sodium carbonate (Na2CO3) could increase the retentate phenol concentration and decrease the permeate concentrations of phenol and CPC significantly. (C) 2007 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据