4.6 Article

Analysis of Normal Human Eye with Different Age Groups using Infrared Images

期刊

JOURNAL OF MEDICAL SYSTEMS
卷 33, 期 3, 页码 207-213

出版社

SPRINGER
DOI: 10.1007/s10916-008-9181-5

关键词

Infrared; Image; Ocular; Cornea; Normal; Eye

资金

  1. Tote Fund, Singapore

向作者/读者索取更多资源

The human body temperature is a good health indicator. All objects emit thermal radiation as a function temperature and wavelength for all wavelengths. The wavelength of infrared rays lies between visible and microwave radiations ranging between 700 nm to 0.1 mm. Infrared (IR) imaging is relatively inexpensive, noninvasive and harmless. Nowadays, it is widely used in the medical field for diagnosis. In this work, we have applied image processing techniques on the IR images of the eye for the analysis of the ocular surface temperature (OST) of the normal subjects of three categories (young, middle and old ages). In our study, 67 IR normal images were analyzed. Two parameters, average ocular temperature and the temperature deviation were proposed to study the variability of OST in different normal category subjects. Our study shows that, the two parameters proposed, show distinct ranges for different groups with 'p' values less than 0.05.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据