4.4 Article

Comparison of the activation time effects and the internal energy distributions for the CID, PQD and HCD excitation modes

期刊

JOURNAL OF MASS SPECTROMETRY
卷 49, 期 6, 页码 498-508

出版社

WILEY
DOI: 10.1002/jms.3365

关键词

activation time; RRKM modeling; CID; PQD; HCD; internal energy distribution; metabolomics

资金

  1. CNRS
  2. UPMC
  3. CEA/DAM

向作者/读者索取更多资源

Reproducibility among different types of excitation modes is a major bottleneck in the field of tandem mass spectrometry library development in metabolomics. In this study, we specifically evaluated the influence of collision voltage and activation time parameters on tandem mass spectrometry spectra for various excitation modes [collision-induced dissociation (CID), pulsed Q dissociation (PQD) and higher-energy collision dissociation (HCD)] of Orbitrap-based instruments. For this purpose, internal energy deposition was probed using an approach based on Rice-Rampserger-Kassel-Marcus modeling with three thermometer compounds of different degree of freedom (69, 228 and 420) and a thermal model. This model treats consecutively the activation and decomposition steps, and the survival precursor ion populations are characterized by truncated Maxwell-Boltzmann internal energy distributions. This study demonstrates that the activation time has a significant impact on MS/MS spectra using the CID and PQD modes. The proposed model seems suitable to describe the multiple collision regime in the PQD and HCD modes. Linear relationships between mean internal energy and collision voltage are shown for the latter modes and the three thermometer molecules. These results suggest that a calibration based on the collision voltage should provide reproducible for PQD, HCD to be compared with CID in tandem in space instruments. However, an important signal loss is observed in PQD excitation mode whatever the mass of the studied compounds, which may affect not only parent ions but also fragment ions depending on the fragmentation parameters. A calibration approach for the CID mode based on the variation of activation time parameter is more appropriate than one based on collision voltage. In fact, the activation time parameter in CID induces a modification of the collisional regime and thus helps control the orientation of the fragmentation pathways (competitive or consecutive dissociations). Copyright (c) 2014 John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据