4.5 Article

Influence of applied magnetic field strength and frequency response of pick-up coil on the magnetic barkhausen noise profile

期刊

JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS
卷 345, 期 -, 页码 208-214

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jmmm.2013.06.038

关键词

Magnetic Barkhausen noise; Frequency spectrum; Gear steel; Carburised steel; Tempered steel

资金

  1. Department of Science and Technology, Government of India for the BOYSCAST Fellowship
  2. Banaras Hindu University

向作者/读者索取更多资源

The influence of applied magnetic field strength and frequency response of the pick-up coil on the shape of Magnetic Barkhausen Noise (MBN) profile have been studied. The low frequency MBN measurements have been carried out using 5 different MBN pick-up coils at two different ranges of applied magnetic field strengths on quenched and tempered (QT) and case-carburised and tempered (CT) 18CrNiMo7 steel bar samples. The MBN pick-up coils have been designed to obtain different frequency response such that the peak frequency response varies from similar to 4 kHz to similar to 32 kHz and the amplitude of low frequency signals decreases gradually. At lower applied magnetic field strength of +/- 14,000 A/m, all the pick-up coils produced a single peak MBN profile for both QT and CT sample. However, at higher applied magnetic field strength of +/- 22,000 A/m, the MBN profile showed two peaks for both QT and CT samples for pick-up coils with peak frequency response up to similar to 17 kHz. Also, there is systematic reduction in peak 2 for QT sample and asymmetric reduction in the heights of peak 1 and peak 2 for CT sample with increase in peak frequency response of the pick-up coils. The decreasing sensitivity of pick-up coils with increasing peak frequency response to MBN signal generation is indicated by the gradual reduction in width of MBN profile and height of peak 2 in the QT sample. The drastic reduction in peak 1 as compared to peak 2 in the CT sample shows the effect of decreasing low frequency response of the pick-up coils on lowering skin-depth of MBN signal detection. This study clearly suggests that it is essential to optimise both maximum applied magnetic field strength and frequency response of the MBN pick-up coil for maximising the shape of the MBN profile for appropriate correlation with the magnetisation process and hence the material properties. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据