4.7 Article

Highly Efficient Respiratory Motion Compensated Free-Breathing Coronary MRA Using Golden-Step Cartesian Acquisition

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 41, 期 3, 页码 738-746

出版社

WILEY
DOI: 10.1002/jmri.24602

关键词

coronary MRI; image navigator; respiratory motion correction; undersampling

资金

  1. Institute for Health Research (NIHR) Biomedical Research Centre at Guy's and St Thomas' NHS Foundation Trust
  2. King's College London
  3. FONDECYT [11110053]
  4. EPSRC [EP/H046410/1] Funding Source: UKRI
  5. British Heart Foundation [RG/12/1/29262] Funding Source: researchfish
  6. Engineering and Physical Sciences Research Council [EP/H046410/1] Funding Source: researchfish

向作者/读者索取更多资源

PurposeTo develop an efficient 3D affine respiratory motion compensation framework for Cartesian whole-heart coronary magnetic resonance angiography (MRA). Materials and MethodsThe proposed method achieves 100% scan efficiency by estimating the affine respiratory motion from the data itself and correcting the acquired data in the reconstruction process. For this, a golden-step Cartesian sampling with spiral profile ordering was performed to enable reconstruction of respiratory resolved images at any breathing position and with different respiratory window size. Affine motion parameters were estimated from image-based registration of 3D undersampled respiratory resolved images reconstructed with iterative SENSE and motion correction was performed directly in the reconstruction using a multiple-coils generalized matrix formulation method. This approach was tested on healthy volunteers and compared against a conventional diaphragmatic navigator-gated acquisition using quantitative and qualitative image quality assessment. ResultsThe proposed approach achieved 47 12% and 59 +/- 6% vessel sharpness for the right (RCA) and left (LAD) coronary arteries, respectively. Also, good quality visual scores of 2.4 +/- 0.74 and 2.44 +/- 0.86 were observed for the RCA and LAD (scores from 0, no to 4, excellent coronary vessel delineation). A not statically significant difference (P = 0.05) was found between the proposed method and an 8-mm navigator-gated and tracked scan, although scan efficiency increased from 61 +/- 10% to 100%. ConclusionWe demonstrate the feasibility of a new 3D affine respiratory motion correction technique for Cartesian whole-heart CMRA that achieves 100% scan efficiency and therefore a predictable acquisition time. This approach yields image quality comparable to that of an 8-mm navigator-gated acquisition with lower scan efficiency. Further evaluation of this technique in patients is now warranted to determine its clinical use. J. Magn. Reson. Imaging 2015;41:738-746. (c) 2014 Wiley Periodicals, Inc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据