期刊
JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 33, 期 1, 页码 119-127出版社
WILEY
DOI: 10.1002/jmri.22390
关键词
magnetic resonance spectroscopy; steatosis; magnetic resonance imaging; fat quantification; robustness
Purpose: To assess the systematic errors in liver methylene fraction (LMF) resulting from fat-fat interference effects with dual- and triple-echo gradient-recalled-echo Dual/Triple GRE) sequences and to test the robustness of these sequences after iron overloading. Materials and Methods: Forty type-2 diabetic patients underwent LMF measurement by 3.0T H-1 magnetic resonance spectroscopy (corrected for T1 and T2 decays) as the reference standard and liver fat fraction (%Fat) measurement by four Dual/Triple GRE sequences with 20 degrees and 60 degrees flip angle (alpha), corrected for T1 recovery. The same four sequences were repeated in eight patients after ferumoxide injection. Corrections for systematic errors were determined from the linear regressions (spectroscopy LMF values over Dual/Triple GRE %Fat values). Robustness was tested using Wilcoxon's signed-rank test. Results: Fat-fat interference effects produced a similar to 10% relative systematic error and T2* decay produced a 1.9%-4.2% absolute systematic error in LMF. When comparing before and after ferumoxide, dual-echo imaging with alpha = 20 degrees and alpha = 60 degrees, even when corrected, showed absolute differences of 7.23% [2.81%-10.25%] (P = 0.0117) and 5.65% [1.89%-8.216.8%] (P = 0.0117), respectively; compared to only 1.17% [0.08%-2.83%] (P = 0.0251) and 1.15% [0.37%-2.73%] (P = 0.2626) with triple-echo imaging and alpha = 20 degrees and alpha = 60 degrees, respectively. Conclusion: Triple-echo imaging with alpha = 60 degrees corrected for both T1 recovery and fat-fat interference effects is robust after superparamagnetic iron oxide (SPIO) administration and can reliably quantify LMF.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据