4.7 Article

Signal features of the atherosclerotic plaque at 3.0 Tesla versus 1.5 Tesla: Impact on automatic classification

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 28, 期 4, 页码 987-995

出版社

WILEY-BLACKWELL
DOI: 10.1002/jmri.21529

关键词

carotid artery; MRI; atherosclerosis; segmentation; field strength

资金

  1. NIH [R01-HL056874, R44-HL070576, P01-HL072262, R01-HL073401]
  2. Pfizer

向作者/读者索取更多资源

Purpose: To investigate the impact of different field strengths on determining plaque composition with an automatic classifier. Materials and Methods: We applied a previously developed automatic classifier-the morphology enhanced probabilistic plaque segmentation (MEPPS) algorithm-to images from 20 subjects scanned at both 1.5 Tesla (T) and 3T. Average areas per slice of lipid-rich core, intraplaque hemorrhage, calcification, and fibrous tissue were recorded for each subject and field strenght. Results: All measurements showed close agreement at the two field strengths, with correlation coefficients of 0.91, 0.93, 0.95, and 0.93, respectively. None of these measurements showed a statistically significant difference between field strengths in the average area per slice by a paired t-test, although calcification tended to be measured larger at 3T (P = 0.09). Conclusion: Automated classification results using an identical algorithm at 1.5T and 3T produced highly similar results, suggesting that with this acquisition protocol, 3T signal characteristics of the atherosclerotic plaque are sufficiently similar to 1.5T characteristics for MEPPS to provide equivalent performance.

作者

我是这篇论文的作者