4.3 Article

The effect of the diffusion time and pulse gradient duration ratio on the diffraction pattern and the structural information estimated from q-space diffusion MR: Experiments and simulations

期刊

JOURNAL OF MAGNETIC RESONANCE
卷 194, 期 2, 页码 230-236

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jmr.2008.07.009

关键词

Diffusion; NMR; q-Space; QSI; Diffraction; Diffusion time; Pulse duration

资金

  1. US-Israel Binational Foundation [353/03]
  2. Intramural Research Program
  3. Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH
  4. EUNICE KENNEDY SHRIVER NATIONAL INSTITUTE OF CHILD HEALTH & HUMAN DEVELOPMENT [ZIAHD000266] Funding Source: NIH RePORTER
  5. EUNICE KENNEDY SHRIVER NATIONAL INSTITUTE OF CHILD HEALTH &HUMAN DEVELOPMENT [Z01HD000266] Funding Source: NIH RePORTER

向作者/读者索取更多资源

q-Space diffusion MRI (QSI) provides a means of obtaining microstructural information about porous materials and neuronal tissues from diffusion data. However, the accuracy of this structural information depends on experimental parameters used to collect the MR data. q-Space diffusion MR performed on clinical scanners is generally collected with relatively long diffusion gradient pulses, in which the gradient pulse duration, delta, is Comparable to the diffusion time, Delta. In this study, we used phantoms, consisting of ensembles Of MiCFOtubes, and mathematical models to assess the effect of the ratio of the diffusion time and the duration of the diffusion pulse gradient, i.e., Delta/delta, on the MR signal attenuation vs. q, and on the measured structural information extracted therefrom. We found that for Delta/delta similar to 1, the diffraction pattern obtained from q-space MR data are shallower than when the short gradient pulse (SGP) approximation is satisfied. For long delta the estimated compartment size is, as expected, smaller than the real size. Interestingly, for Delta/delta similar to 1 the diffraction peaks are shifted to even higher q-values, even when delta is kept constant, giving the impression that the restricted compartments are even smaller than they are. When phantoms composed of microtubes of different diameters are used, it is more difficult to estimate the diameter distribution in this regime. Excellent agreement is found between the experimental results and simulations that explicitly account for the use of long duration gradient pulses. Using such experimental data and this mathematical framework, one can estimate the true compartment dimensions when long and finite gradient pulses are used even when Delta/delta similar to 1. (C) 2008 Elsevier Inc. All rights reserved.