4.8 Article

Energy and environmental comparison of two-stage solutions for commercial refrigeration at low temperature: Fluids and systems

期刊

APPLIED ENERGY
卷 138, 期 -, 页码 133-142

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2014.10.069

关键词

Cascade; Two-stage; Low GWP; TEWI; Energy efficiency; R152a

资金

  1. Jaume I University of Spain [P1.B2013-10]

向作者/读者索取更多资源

International agreements will restrict in the near future the use of high-GWP refrigerants in Europe. These restrictions will favour the implantation of refrigeration systems with low-GWP fluids, especially in applications with high leakage rate. To clarify possible solutions that accomplish the forthcoming F-Gas Regulation, we present simplified models of five two-stage vapour compression refrigeration systems and evaluate them with low-GWP refrigerants (HFC, HFO and naturals). We analyse the energy performance over a wide range of evaporating and environment temperatures and present the TEWI analysis under a same scenario, typical of a centralized commercial refrigeration application. We conclude that, for high-GWP refrigerants, direct emissions have greater weight in TEWI than the indirect ones, so future solutions might be based on low-GWP fluids, in some cases with risk of toxicity or flammability. We observe the indirect two-stage systems (cascades) with CO2 as low temperature fluid are promising solutions, especially for warm regions. (C) 2014 Elsevier Ltd. All rights reserved.