期刊
APPLIED ENERGY
卷 137, 期 -, 页码 402-412出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2014.10.042
关键词
Redox flow battery; Vanadium; Current density; Temperature; Electrolyte flow rates
资金
- Malaysian Ministry of Education (MOE)
- Universiti Malaysia Pahang (UMP), Malaysia
- MOHE under grant Prototype Development Research Grant Scheme (PRGS) [RDU130802]
- UMP [RDU1203104]
This paper describes the experimental characterization of a 25 cm(2) laboratory scale vanadium redox flow battery (V-RFB). The unit cell performance with respect to voltage, coulombic and energy efficiencies under different performance parameters (current densities, operating temperatures, flow rates, electrolyte concentrations and material properties of 5 cm x 5 cm electrodes) are presented. The cell exhibits different characteristics under different operating parameters; the highest energy efficiency is recorded at c.a. 82%, operating at 308 K, 60 mA cm(-2) and 3 cm(3) s(-1) volumetric flow rate for 250 cm(3) electrolytes (each reservoir) of 1.6 mol dm(-3) V(III)/V(IV) in 4 mol dm(-3) H2SO4. Formation charge of the mixture of vanadium species into single electro-active species at positive and negative electrodes are presented. Estimated time for the electro-active species to complete the formation charge using electrochemical calculation of Faraday's constant are presented; a discrepancy of 4.5% is found between the theoretical and experimental data using current density of 80 mA cm(-2). (C) 2014 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐