4.2 Article

Optimization and diagnostic performance of a single multiparameter lineblot in the serological workup of systemic sclerosis

期刊

JOURNAL OF IMMUNOLOGICAL METHODS
卷 379, 期 1-2, 页码 53-60

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jim.2012.03.001

关键词

Anti-extractable nuclear antigen antibodies; Systemic sclerosis; Anti-RNA-polymerase-III antibodies; Anti-PM/Scl antibodies; Lineblot; Diagnostic accuracy

资金

  1. Fund for Scientific Research, Flanders

向作者/读者索取更多资源

Introduction: Detection of systemic sclerosis-associated antibodies (SSc-Ab) in routine clinical practice is mostly restricted to anti-centromere and anti-topoisomerase-I antibodies. However, also other SSc-Ab (e.g. anti-RNA-polymerase-III, anti-PM/Scl, anti-fibrillarin and anti-Th/To) have been shown to be valuable diagnostic and prognostic markers for the disease, but testing methodologies for their detection are laborious and time-consuming. This study aimed to optimize interpretational criteria of a multiparameter lineblot (LB) for the parallel detection of SSc-Ab. We also assessed its global diagnostic value as an alternative for combined conventional techniques (CCT) in the serological workup of systemic sclerosis (SSc) patients. Methods: The presence of SSc-Ab (anti-centromere, anti-topoisomerase-I, anti-RNA-polymerase-III, anti-PM/Scl, anti-fibrillarin and anti-Th/To) was identified by LB on 145 consecutive SSc patients and on 277 disease controls. Diagnostic sensitivity and specificity were calculated for both individual reactivities and the global LB. Cohen's kappa coefficient was used to examine agreement between LB and CCT and guided the definition of final interpretational criteria for LB. Results: Applying the optimal cut-off values and interpretational criteria. LB identified SSc-Ab in 110 SSc patients (sensitivity = 76%) and in 19 disease controls (specificity = 93%). Globally, there was a substantial agreement between CCT and LB (kappa = 0.787, concordance 92.4%). LB and CD' showed a very good correlation (kappa > 0.800) for most SSc-Ab (anti-centromere, anti-topoisomerase-I, anti-RNA-polymerase-III and anti-PM/Scl). The best agreement for anti-RNApolymerase-III and anti-PM/Scl was achieved when positivity for both components was taken as a criterion. Conclusions: LB is a reliable alternative for the laborious and time-consuming conventional techniques in the diagnostic workup of SSc, especially for the detection of anti-centromere, anti-topoisomerase-I, anti-RNA-polymerase-III and anti-PM/Scl. (C) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据