Evaluation of the Vicorder, a novel cuff-based device for the noninvasive estimation of central blood pressure

期刊

JOURNAL OF HYPERTENSION
卷 31, 期 1, 页码 77-85

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/HJH.0b013e32835a8eb1

关键词

applanation tonometry; central blood pressure; hypertension; oscillometric signals; pulse wave analysis; wave reflection

资金

  1. NIHR Cambridge Biomedical Research Centre
  2. Cambridge University Hospitals
  3. Comprehensive Local Research Network
  4. British Heart Foundation
  5. British Heart Foundation [FS/12/8/29377] Funding Source: researchfish

向作者/读者索取更多资源

Objectives: The Vicorder is a new brachial cuff-based device that estimates central blood pressure (cBP) using a brachial-to-aortic transfer function. The aim of this study was to evaluate cBP estimated by the Vicorder. Methods: During cardiac angiography, cBP estimated by the Vicorder and the SphygmoCor was evaluated against simultaneous invasive cBP in 50 patients. The two devices were also compared noninvasively in a separate group of 90 healthy individuals. Results: Central SBP (cSBP) obtained with each device satisfied the American Association for the Advancement of Medical Instrumentation accuracy criteria when peripheral waveforms were calibrated to invasive mean arterial pressure (MAP)/DBP: estimated - invasive cSBP difference, -4.0 +/- 7.4mmHg, Vicorder, P < 0.001; -1.4 +/- 7.9 mmHg, SphygmoCor, P = 0.21. When oscillometric brachial SBP/DBP was used for peripheral waveform calibration, cSBP was underestimated by Vicorder (Delta - 6.4 +/- 7.4mmHg, P < 0.001 versus invasive) and more so by SphygmoCor (Delta - 11.9 +/- 7.2mmHg, P < 0.001 versus invasive). Conversely, cSBP was more closely estimated by SphygmoCor when waveforms were calibrated to brachial MAP/DBP (Delta - 2.8 +/- 9.4 mmHg, P = 0.04 versus invasive). In the noninvasive study, Vicorder cSBP correlated well with SphygmoCor cSBP when SphygmoCor waveforms were calibrated to brachial MAP/DBP (121 +/- 16 versus 121 +/- 17 mmHg, P = 0.2) but not when brachial SBP/DBP was used for calibration (115 +/- 19 mmHg, P < 0.001). Conclusion: The Vicorder and SphygmoCor devices provide reliable estimates of cSBP when calibrated to invasive pressure. When calibrated to brachial BP, both devices underestimated cSBP, although this was attenuated when SphygmoCor was calibrated to brachial MAP/DBP. Vicorder may be a simple alternative to tonometry-based methods for noninvasive assessment of cBP.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据