4.5 Article

Speckle tracking echocardiography as a new technique to evaluate right ventricular function in patients with left ventricular assist device therapy

期刊

JOURNAL OF HEART AND LUNG TRANSPLANTATION
卷 32, 期 4, 页码 424-430

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.healun.2012.12.010

关键词

left ventricular assist device; speckle tracking echocardiography; right ventricular systolic function; right ventricular myocardial deformation; strain; right ventricular failure

向作者/读者索取更多资源

BACKGROUND: Right ventricular (RV) systolic function has a critical role in determining the clinical outcome and the success of using left ventricular assist devices (LVADs) in patients with refractory heart failure. RV deformation analysis by speckle tracking echocardiography (STE) has recently allowed a deeper analysis of RV longitudinal function. The aim of the study was to observe RV function by STE in patients with advanced heart failure before and after LVAD implantation. METHODS: Transthoracic echo Doppler was performed in 10 patients referred for LVAD therapy at baseline and with serial echocardiograms after LVAD implantation. In a sub-group of 4 patients, an echocardiographic evaluation was also made after intra-aortic balloon pump (IABP) support was initiated and before LVAD implantation. All echocardiographic images were analyzed off-line to calculate the free wall RV longitudinal strain (RVLS). RESULTS: Three patients who presented the lowest free wall RVLS values at baseline, showed a progressive decline of RVLS after LVAD implant, presenting finally RV failure; however, patients with higher values of RVLS at baseline presented a further and overt increase of strain values in the course of follow-up. The overall performance for the prediction of RV failure after LVAD implant was greatest for free wall RVLS (area under the curve, 0.93). For the sub-group receiving the IABP as an intermediate step, only 2 patients with an increase of RVLS after IABP implantation also showed an increase of RVLS levels, after subsequent LVAD implantation. The 2 patients without an increase of RVLS after IABP implantation also presented with RV failure after LVAD therapy. CONCLUSIONS: This study of 10 patients indicates that the new parameter of RVLS, representing RV myocardial deformation, may have important clinical implications for the selection and management of LVAD patients. A large multicenter study is required to confirm these observations and to quantify the clinical significance of changes in RVLS value. J Heart Lung Transplant 2013; 32: 424-430 (C) 2013 International Society for Heart and Lung Transplantation. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据