4.7 Article

Co-firing of oil sludge with coal-water slurry in an industrial internal circulating fluidized bed boiler

期刊

JOURNAL OF HAZARDOUS MATERIALS
卷 167, 期 1-3, 页码 817-823

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jhazmat.2009.01.061

关键词

Oil sludge; Co-firing; Internal circulating fluidized bed; Emission

资金

  1. National High Technology Research and Development Program of China [2007AA05Z333]
  2. China Postdoctoral Science Foundation [20070410177]

向作者/读者索取更多资源

Incineration has been proven to be an alternative for disposal of sludge with its unique characteristics to minimize the volume and recover energy. In this paper, a new fluidized bed (FB) incineration system for treating oil sludge is presented. Co-firing of oil sludge with coal-water slurry (CWS) was investigated in the new incineration system to study combustion characteristics, gaseous pollutant emissions and ash management. The study results show the co-firing of oil sludge with CWS in FB has good operating characteristic. CWS as an auxiliary fuel can flexibly control the dense bed temperatures by adjusting its feeding rate. All emissions met the local environmental requirements. The CO emission was less than 1 ppm or essentially zero; the emissions of SO2 and NOx were 120-220 and 120-160 mg/Nm(3), respectively. The heavy metal analyses of the bottom ash and the fly ash by ICP/AES show that the combustion ashes could be recycled as soil for farming. (C) 2009 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据