4.2 Article

Gliding Resistance and Strength of Composite Sutures in Human Flexor Digitorum Profundus Tendon Repair: An In Vitro Biomechanical Study

期刊

JOURNAL OF HAND SURGERY-AMERICAN VOLUME
卷 34A, 期 1, 页码 87-92

出版社

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.jhsa.2008.09.020

关键词

Gliding resistance; suture; tendon; tendon repair

资金

  1. National Institutes of Health [R25 GM 55252]
  2. Mayo Foundation
  3. NATIONAL INSTITUTE OF ARTHRITIS AND MUSCULOSKELETAL AND SKIN DISEASES [R01AR044391] Funding Source: NIH RePORTER
  4. NATIONAL INSTITUTE OF GENERAL MEDICAL SCIENCES [R25GM055252] Funding Source: NIH RePORTER

向作者/读者索取更多资源

Purpose Although the strength of a tendon repair is clearly important, the friction of the repair is also a relevant consideration. The purpose of this study was to characterize the frictional coefficient, gliding resistance, and breaking strength of suture materials and a suture construct commonly used for flexor tendon repair. Methods We measured the friction coefficients of 3-0 braided nylon enclosed in a smooth nylon outer shell (Supramid, S. Jackson, Alexandria, VA), 3-0 braided polyester coated with polybutilate (Ethibond, Ethicon, Somerville, NJ), and 3-0 braided polyester/monofilament polyethylene composite (FiberWire, Arthrex, Naples, FL) sutures, We also measured the gliding resistance, linear breaking strength, and resistance to gapping of zone 2 modified Pennington tendon repairs with the 2 lowest-friction sutures in 20 human cadaveric flexor digitorum profundus tendons. Results The braided polyester/monofilament polyethylene composite had a significantly lower friction coefficient (0.054) than either the coated polyester (0.076) or nylon (0.130) sutures. The gliding resistances of the repaired tendons with braided/monofilament polyethylene composite suture and those of coated, braided polyester were similar. The strength of the 2 repairs (force to produce a 2 mm gap) and resistance to gap formation were also not significantly different. Conclusions Braided polyester composite is a low-friction suture material. However, when this suture was used for tendon repair with a locking suture technique, it did not show a significant effect on the gliding resistance and repair strength compared with the same repair using a coated polyester Suture. (J Hand Surg 2009;34A:87-92. (C) 2009 Published by Elsevier Inc. on behalf of the American Society for Surgery of the Hand.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据