4.6 Article

Loop-Mediated Isothermal Amplification (LAMP) for the Rapid and Sensitive Detection of Salmonella Typhimurium from Pork

期刊

JOURNAL OF FOOD SCIENCE
卷 75, 期 3, 页码 M165-M172

出版社

WILEY
DOI: 10.1111/j.1750-3841.2010.01554.x

关键词

LAMP; pork; Salmonella

资金

  1. Natl. Pork Board

向作者/读者索取更多资源

Loop-mediated isothermal amplification (LAMP) is a novel molecular detection method that is more rapid and simpler than PCR. Products can be detected by turbidity using one temperature without the need for expensive PCR equipment. Our objective was to sensitively detect Salmonella Typhimurium from pork products within 1 d using the LAMP assay. Pork chop and pork sausage samples (25 g) were inoculated with high (10(8) to 10(6) CFU) and low (10(5) to 10(0) CFU) inocula of S. Typhimurium. Serial dilutions in phosphate buffered saline were plated on XLT4 agar either immediately or after selective preenrichment in tetrathionate broth (225 mL) for 10-h at 37 degrees C. Nucleic acid was extracted using the TRIzol (R) method from 1-mL samples. The LAMP assay using 6 specific invA gene primers and Bst DNA polymerase reaction mix was carried out at 62 degrees C for 90 min in a waterbath. Turbid products were detected visually and by agarose gel electrophoresis. Improved Salmonella detection at 102 CFU/25 g for both pork chop and sausage was obtained after 10-h enrichment and 106 CFU/25 g without enrichment for both products. This assay can detect Salmonella from pork within 1 d, significantly faster than traditional methods that take >5 d. This method shows tremendous potential for routine diagnostics and monitoring of Salmonella by the pork industry. Practical Application: The novel loop-mediated isothermal amplification (LAMP) assay is a rapid, specific, and sensitive method that has potential application for routine diagnostics of Salmonella from pork products. The isothermal method does not require expensive equipment such as a PCR thermocylcer but only a simple waterbath for amplification within 90 min. Detection is even simpler by visual eye or turbidimeters that are less expensive than fluorescent spectrophotometers or real-time PCR machines. All these advantages make it a practical approach for routine use by processing industries to rapidly detect Salmonella in their environment and to implement appropriate control strategies. To improve detection sensitivities, preenrichment followed by selective enrichment may be necessary. Even so, the entire assay can be completed at the most within two 8-h working shifts.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据