4.0 Article

Verification of a depth-integrated sample arm as a means to reduce solids stratification bias in urban stormwater sampling

期刊

JOURNAL OF ENVIRONMENTAL MONITORING
卷 14, 期 4, 页码 1138-1144

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c2em10999a

关键词

-

向作者/读者索取更多资源

A new water sample collection system was developed to improve representation of solids entrained in urban stormwater by integrating water-quality samples from the entire water column, rather than a single, fixed point. The depth-integrated sample arm (DISA) was better able to characterize suspended-sediment concentration and particle size distribution compared to fixed-point methods when tested in a controlled laboratory environment. Median suspended-sediment concentrations overestimated the actual concentration by 49 and 7% when sampling the water column at 3- and 4-points spaced vertically throughout the water column, respectively. Comparatively, sampling only at the bottom of the pipe, the fixed-point overestimated the actual concentration by 96%. The fixed-point sampler also showed a coarser particle size distribution compared to the DISA which was better able to reproduce the average distribution of particles in the water column over a range of hydraulic conditions. These results emphasize the need for a water sample collection system that integrates the entire water column, rather than a single, fixed point to properly characterize the concentration and distribution of particles entrained in stormwater pipe flow.