4.2 Article

Environmental Factors and the Application of Hydrogen Peroxide for the Removal of Toxic Cyanobacteria from Waste Stabilization Ponds

期刊

JOURNAL OF ENVIRONMENTAL ENGINEERING
卷 137, 期 10, 页码 952-960

出版社

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)EE.1943-7870.0000401

关键词

Cyanobacteria; Hydrogen peroixide; Wastewater; Wastewater treatment plant; Waste stabilization pond; Spectrofluorescence; Remediation

资金

  1. Australian Research Council [LP0776571]
  2. Australian Research Council [LP0776571] Funding Source: Australian Research Council

向作者/读者索取更多资源

Toxin-producing cyanobacteria constitute a serious threat to human and environmental health. It is thus essential that an effective treatment guarantees the removal of cyanobacteria from wastewater before its inclusion in water recycling or environmental flow. Hydrogen peroxide (H2O2) has been shown to induce cyanobacterial decay in laboratory cultures. However, its application for the removal of cyanobacteria from wastewater treatment ponds under environmental conditions has not been investigated. To examine the effects of environmental factors, field trials were performed at both the mesocosm and full-scale levels. The mesocosm trial was completed under field conditions of incident radiation, with various H2O2 concentrations. A concentration of 1.1 x 10(-4) gH(2)O(2)/mu g ch1-alpha resulted in a 32% decrease in cyanobacterial concentration after 24 h, and this approximate concentration was then applied to a wastewater treatment pond in the full-scale trial. In the full-scale experiment, intense spatial and temporal monitoring of phytoplankton concentrations and temperature throughout the pond was performed. Cyanobacterial biomass was reduced by 57% and total phytoplankton biomass by 70% within 48 h of H2O2 addition. : Mixing and radiation were shown to control the depth reached by H2O2 following addition to the ponds. The synergistic effect of H2O2 addition with environmental factors increased the effectiveness of cyanobacterial removal compared with laboratory experiments. The concentration of H2O2 required for the removal of cyanobacteria under field conditions may be decreased from laboratory studies by an order of magnitude. DOI: 10.1061/(ASCE)EE.1943-7870.0000401. (C) 2011 American Society of Civil Engineers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据