4.3 Article

Unsteady Pressure Measurements With a Fast Response Cooled Probe in High Temperature Gas Turbine Environments

出版社

ASME
DOI: 10.1115/1.4002276

关键词

-

资金

  1. EU [AST5-CT-2006-030696]
  2. European Commission

向作者/读者索取更多资源

This paper presents the first experimental engine and test rig results obtained from a fast response cooled total pressure probe. The first objective of the probe design was to favor continuous immersion of the probe into the engine to obtain a time series of pressure with a high bandwidth and, therefore, statistically representative average fluctuations at the blade passing frequency. The probe is water cooled by a high pressure cooling system and uses a conventional piezoresistive pressure sensor, which yields, therefore, both time-averaged and time-resolved pressures. The initial design target was to gain the capability of performing measurements at the temperature conditions typically found at high pressure turbine exit (800-1100 degrees C) with a bandwidth of at least 40 kHz and in the long term at combustor exit (2000 K or higher). The probe was first traversed at the turbine exit of a Rolls-Royce Viper turbojet engine at exhaust temperatures around 750 degrees C and absolute pressure of 2.1 bars. The probe was able to resolve the high blade passing frequency (approximate to 23 kHz) and several harmonics of up to 100 kHz. Besides the average total pressure distributions rom the radial traverses, phase-locked averages and random unsteadiness are presented. The probe was also used in a virtual three-hole mode yielding unsteady yaw angle, static pressure, and Mach number. The same probe was used for measurements in a Rolls-Royce intermediate pressure burner rig. Traverses were performed inside the flame tube of a kerosene burner at temperatures above 1600 degrees C. The probe successfully measured the total pressure distribution in the flame tube and typical frequencies of combustion instabilities were identified during rumble conditions. The cooling performance of the probe is compared with estimations at the design stage and found to be in good agreement. The frequency response of the probe is compared with cold shock-tube results and a significant increase in the natural frequency of the line-cavity system formed by the conduction cooled screen in front of the miniature pressure sensor were observed. [DOI: 10.1115/1.4002276]

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据