4.3 Article

Comparison of Countercurrent Flow Limitation Experiments Performed in Two Different Models of the Hot Leg of a Pressurized Water Reactor With Rectangular Cross Section

出版社

ASME
DOI: 10.1115/1.4002884

关键词

-

资金

  1. German Federal Ministry of Economics and Technology [150 1329]

向作者/读者索取更多资源

In order to investigate the two-phase flow behavior during countercurrent flow limitation in the hot leg of a pressurized water reactor, two test models were built: one at the Kobe University and the other at the TOPFLOW test facility of Forschungszentrum Dresden-Rossendorf (FZD). Both test facilities are devoted to optical measurement techniques; therefore, a flat hot leg test section design was chosen. Countercurrent flow limitation (CCFL) experiments were performed, simulating the reflux condenser cooling mode appearing in some accident scenarios. The fluids used were air and water, both at room temperature. The pressure conditions were varied from atmospheric at Kobe to 3.0 bars absolute at TOPFLOW. According to the presented review of literature, very few data are available on flooding in channels with a rectangular cross section, and no experiments were performed in the past in such flat models of a hot leg. Commonly, the macroscopic effects of CCFL are represented in a flooding diagram, where the gas flow rate is plotted versus the discharge water flow rate, using the nondimensional superficial velocity (also known as Wallis parameter) as coordinates. However, the classical definition of the Wallis parameter contains the pipe diameter as characteristic length. In order to be able to perform comparisons with pipe experiments and to extrapolate to the power plant scale, the appropriate characteristic length should be determined. A detailed comparison of the test facilities operated at the Kobe University and at FZD is presented. With respect to the CCFL behavior, it is shown that the essential parts of the two hot leg test sections are very similar. This geometrical analogy allows us to perform meaningful comparisons. However, clear differences in the dimensions of the cross section (HxW=150x10 mm(2) in Kobe, 250x50 mm(2) at FZD) make it possible to point out the right characteristic length for hot leg models with rectangular cross sections. The hydraulic diameter, the channel height, and the Laplace critical wavelength (leading to the Kutateladze number) were tested. A comparison of our own results with similar experimental data and empirical correlations for pipes available in literature shows that the channel height is the characteristic length to be used in the Wallis parameter for channels with rectangular cross sections. However, some limitations were noticed for narrow channels, where CCFL is reached at lower gas fluxes, as already observed in small scale hot legs with pipe cross sections. [DOI: 10.1115/1.4002884]

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据