Introduction: From experiments, we know that the heterogeneity of action potential duration and morphology is an important mechanism of ventricular tachyarrhythmia. Electrocardiogram (ECG) markers of repolarization lability are known; however, lability of depolarization has not been systematically studied. We propose a novel method for the assessment of variability of both depolarization and repolarization phases of the cardiac cycle. Methods: Baseline orthogonal ECGs of 81 patients (mean +/- SD age, 56 +/- 13 years; 61 male [75%]) with structural heart disease and implanted single-chamber implantable cardioverter defibrillator (ICD) were analyzed. Clean 30-beat intervals with absence of premature beats were then selected. Baseline wandering was corrected before analysis. Peaks of R wave and peaks of T wave were detected for each beat, and the axis magnitude was calculated. The peaks were plotted to show clouds of peaks and then used to construct a convex hull, and the volumes of the R peaks cloud and T peaks cloud and ratio of volumes were calculated. Results: During a mean (SD) follow-up period of 13 (10) months, 9 of the 81 patients had sustained ventricular tachycardia or ventricular fibrillation (VT/VF) and received appropriate ICD therapies. All ICD events were adjudicated by three independent electrophysiologists. There was no statistically significant difference in the volume of T-wave peaks or R-wave peaks between patients with and without VT or VF during follow-up; however, R/T peaks cloud volume ratio was significantly lower in patients with subsequent VT/VF (22.4 +/- 25.4 versus 13.1 +/- 7.9, P = .024). Conclusions: Larger volume of T peaks cloud, measured during 30 beats of three-dimensional ECG, is associated with higher risk of sustained ventricular tachyarrhythmias and appropriate ICD therapies. New method to assess temporal variability of repolarization in three-dimensional ECGs by measuring volume of peak clouds shows potential for further exploration for VT/VF risk stratification. (C) 2010 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据