Electrochemical detection of butylated hydroxyanisole based on glassy carbon electrode modified by iridium oxide nanoparticles

期刊

JOURNAL OF ELECTROANALYTICAL CHEMISTRY
卷 717, 期 -, 页码 147-152

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.jelechem.2014.01.013

关键词

Butylated hydroxyanisole; Nano-iridium oxide; Chemical modified electrode; Electrocatalytic

向作者/读者索取更多资源

The present study describes a new approach for the investigation of electrocatalytic oxidation of butylated hydroxyanisole (BHA) by using a glassy carbon electrode modified by iridium oxide nanoparticles (GCE/IrOxNPs). IrOxNPs are grown on a GCE by electrodepositing method. It was observed that GCE/IrOxNPs showed a significant electrocatalytic activity toward BHA oxidation. Various experimental parameters influencing the electrochemical behavior of the modified electrode were optimized by varying the scan rates and pH. Cyclic voltammetric studies showed that the catalytic peak current of GCE/IrOxNPs was amplified approximately to 5 times in comparison with the bare GCE. The detection limit, sensitivity, and catalytic rate constant (k(cat)) of the modified electrode toward BHA were 100 nM, 113 nA mu M-1, and 1.1 x 104 M-1 s(-1), respectively, at linear concentration range of up to 280 mu M. The modified electrode showed a good electrochemical response in terms of sensitivity and stability. (C) 2014 Elsevier B.V. All rights reserved.