4.6 Article

Seismic Performance of Square Concrete Columns Confined with Glass Fiber-Reinforced Polymer Ties

期刊

出版社

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)CC.1943-5614.0000884

关键词

Square columns; Glass fiber-reinforced polymers (GFRP); Ties; Hybrid; Concrete confinement; Seismic resilience; Reinforced concrete; Ductility

资金

  1. Natural Sciences and Engineering Research Council of Canada (NSERC)
  2. IC-IMPACTS, NSERC Network of Centers of Excellence

向作者/读者索取更多资源

This paper assesses the seismic response of square concrete columns internally confined with glass fiber-reinforced polymers (GFRP). Tests were conducted under simulated earthquake loads on eight full-scale 305 x 305 mm columns reinforced with GFRP rectilinear ties and steel longitudinal bars. Shear versus deflection and moment versus curvature responses along with various ductility parameters were used to evaluate the performance of the columns. Results showed that the GFRP ties provide effective confinement to the concrete core until a rupture strain much larger than the steel yield strain. The influence of tie configuration on specimen behavior was found to be significant. An approximately 4% ultimate drift ratio was observed for properly confined columns tested under axial load of 42% of the column axial load capacity. The current design code provisions and guidelines for GFRP ties were found to be ambiguous and lacking in several aspects; suggestions are made for improvement. (c) 2018 American Society of Civil Engineers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据