Impact of guided bone regeneration and defect dimension on wound healing at chemically modified hydrophilic titanium implant surfaces: an experimental study in dogs

期刊

JOURNAL OF CLINICAL PERIODONTOLOGY
卷 37, 期 5, 页码 474-485

出版社

WILEY
DOI: 10.1111/j.1600-051X.2010.01551.x

关键词

animal study; chronic-type defect; guided bone regeneration; hydrophilicity; implant surfaces

资金

  1. ITI Foundation [5282007]
  2. Institute Straumann AG, Basel, Switzerland

向作者/读者索取更多资源

P>Objectives The aim of the present study was to evaluate the impact of guided bone regeneration and defect dimension on wound healing at chemically modified titanium implant surfaces (modSLA). Materials and Methods ModSLA implants were placed at chronic-type lateral ridge defects of different heights (H1-H4: 2, 4, 6 and 8 mm) and randomly allocated to either (a) GBR (polyethylene glycol membrane + biphasic calcium phosphate) or (b) untreated control. At 2 and 8 weeks (n=6 dogs each), dissected blocks were processed for histomorphometrical analysis [e.g., percentage linear fill (PLF), regenerated area (RA)]. Results At 8 weeks, both groups revealed comparable mean PLF (%) [Control: H1 (26.1 +/- 5.8)-H4 (60.4 +/- 11.8); GBR: H1 (8.3 +/- 5.3)-H4 (50.7 +/- 23.1)] and RA (mm2) [Control: H1 (2.5 +/- 0.4)-H4 (7.4 +/- 4.1); GBR: H1 (1.8 +/- 1.0)-H4 (10.8 +/- 5.9)] values. A significant difference was observed for the mean PLF values at H1 defects. Conclusion It was concluded that (i) modSLA titanium implants supported bone regeneration and osseointegration at H1-H4 defects and (ii) the present GBR procedure did not seem to improve the outcome of vertical bone regeneration, but tended to increase the mean RA values.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据