4.7 Article

Impact of Blood Cultures Drawn by Phlebotomy on Contamination Rates and Health Care Costs in a Hospital Emergency Department

期刊

JOURNAL OF CLINICAL MICROBIOLOGY
卷 47, 期 4, 页码 1021-1024

出版社

AMER SOC MICROBIOLOGY
DOI: 10.1128/JCM.02162-08

关键词

-

向作者/读者索取更多资源

We conducted a prospective comparison of blood culture contamination rates associated with dedicated phlebotomists and nonphlebotomy staff in the emergency department (ED) at Parkland Memorial Hospital in Dallas, TX. In addition, hospital charges and lengths of stay were determined for patients with negative, false-positive, and true-positive blood culture results. A total of 5,432 blood culture collections from two ED areas, the western wing of the ED (ED west) and the nonwestern wing of the ED (ED nonwest), were evaluated over a 13-month period. Phlebotomists drew 2,012 (55%) of the blood cultures in ED west while nonphlebotomy staff drew 1,650 (45%) in ED west and 1,770 (100%) in ED nonwest. The contamination rates of blood cultures collected by phlebotomists were significantly lower than those collected by nonphlebotomists in ED west (62/2,012 [3.1%] versus 122/1,650 [7.4%]; P < 0.001). Similar results were observed when rates between phlebotomists in ED west and nonphlebotomy staff in ED nonwest were compared (62/2,012 [3.1%] versus 100/1,770 [5.6%]; P < 0.001). Comparison of median patient charges between negative and false-positive episodes ($18,752 versus $27,472) showed $8,720 in additional charges per contamination event while the median length of stay increased marginally from 4 to 5 days. By utilizing phlebotomists to collect blood cultures in the ED, contamination rates were lowered to recommended levels, with projected reductions in patient charges of approximately $4.1 million per year.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据