期刊
JOURNAL OF CLEANER PRODUCTION
卷 39, 期 -, 页码 321-328出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.jclepro.2012.05.049
关键词
Rectisol wash; Model verification; Sour gas emission; Heat recovery
资金
- BP International Limited, UK
Rectisol wash is becoming increasingly popular as a sour gas treating, especially integrated in the polygeneration systems. Two configurations of single-stage Rectisol wash and two-stage configuration are analysed and simulated in Aspen Plus for the property model rectification and the process comparison. The model PC-SAFT is revised for binary interaction parameters modification, and the revised model is verified based on practical process design data. The revised PC-SAFT is determined as the thermodynamic property model in the process simulation. The two configurations compare in the aspects of the acid gas removal ability, heat recovery, equipments requirement, power consumptions, and environment emission and environment costs. (c) 2012 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据