4.5 Article

Two rapid ultra performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) methods with common sample pretreatment for therapeutic drug monitoring of immunosuppressants compared to immunoassay

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jchromb.2013.03.014

关键词

Immunosuppressants; Therapeutic drug monitoring; Liquid chromatography-tandem mass spectrometry

资金

  1. Polish National Center of Research and Development [N R13 014410]

向作者/读者索取更多资源

Therapeutic drug monitoring of immunosuppressive agents is a critical and essential part of patient therapy after organ transplantation. We have developed high-throughput, robust, and rapid liquid chromatography-tandem mass spectrometry (UPLC/MS/MS) methods with common pretreatment procedures for simultaneous quantification of four immunosuppressive agents (everolimus, sirolimus, tacrolimus, and cyclosporin A) in whole blood and one immunosuppressant (mycophenolic acid) in plasma. The new approach used in this work is based on improved sample preparation procedures allowing the analysis of five immunosuppressive drugs. Whole blood was prepared by transferring 100 mu L of blood into a 1.5-mL silanized conical test tube. Zinc sulfate solution (150 mu L), containing deuterated internal standards, was added to perform hemolysis. The samples were vortexing for 10 s, followed by the addition of 250 mu L acetonitrile, containing internal standard for cyclosporin A, to precipitate proteins. The mixture was vortexed for 1 min and centrifuged for 2 min at 14,000 rpm. The whole supernatant was transferred to a vial. To prepare blood plasma, the hemolysis step involving the addition of zinc sulfate was omitted and, instead of acetonitrile, methanol was used as the solvent for the internal standard (mycophenolic acid-d3). The volumes of chemicals used in this procedure were the same as those used in the procedure for immunosuppressants in whole blood. The basic validation parameters for the analytical methods were limits of detection (0.5 ng/mL for everolimus, sirolimus and tacrolimus, 25 ng/mL for cyclosporin A and 100 ng/mL for mycophenolic acid), precision (<15%), recovery (>84%), repeatability and reproducibility. Possible mutual ion suppression was eliminated in the presence of internal standards. The method developed for the quantitation of immunosuppressants in whole blood was used to analyze 276 patient samples containing tacrolimus and 55 samples containing cyclosporin A. The results from LC/MS/MS were compared to those obtained from immunoassays of the same samples. Immunoassays significantly overestimated the concentrations of immunosuppressants. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据