4.5 Article

Measurement of plasma 5-hydroxyindole acetic acid by liquid chromatography tandem mass spectrometry-Comparison with HPLC methodology

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jchromb.2010.01.010

关键词

5-Hydroxyindole acetic acid; Carcinoid; Liquid chromatography; Tandem mass spectrometry

向作者/读者索取更多资源

In patients with carcinoid disease, urinary concentration of the serotonin metabolite 5-hydroxyindole acetic acid (5-HIAA) is currently used to monitor disease progression or response to treatment as it is the metabolic end-product resulting from free and stored serotonin turnover. However. due to the undignified, cumbersome and error-prone nature of 24-h urine collections, there is constant pressure to replace them. It has been demonstrated using high performance liquid chromatography (HPLC) with fluorescence detection technology that plasma can achieve this, with the added advantage that it can be used for diagnostic purposes also. Here we describe a much simpler method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) that is twice as fast as a HPLC method currently in routine use. The sample preparation protocol requires 50 mu L of plasma and a simple protein precipitation step facilitated by acetonitrile. Chromatography was performed on a Phenomenex C18 Security Guard (TM) column coupled to a SIELC Primesep B reversed-phase, anion-exchange dual chemistry column and methanolic mobile phase gradient elution. Eluant was directly connected to a Waters (R) Quattro Premier (TM) XE tandem mass spectrometer operating in positive ion mode. We detected multiple reaction monitoring transitions m/z 191.9 > 145.6 and 193.9 > 147.6 for 5-HIAA and d2-5-HIAA respectively, which co-eluted at 2.1 min. Ion suppression was negligible, recovery from spiked plasma was 103% (range 97-113%) and the method showed good linearity to 10,000nmol/L (r(2) =0.999). Within-batch and between-batch imprecision was <10% and bias <15% at 3 concentrations, the limit of detection was 5 nmol/L and lower limit of quantitation 15 nmol/L. No interference was observed with L-tryptophan or 5-hydroxytryptamine. Comparison of LC-MS/MS and HPLC showed good agreement between the two methods but this LC-MS/MS assay displays several advantages; it requires 10-fold less sample, has a simpler extraction procedure and extended linearity, thus increasing laboratory throughput, lowering reagent costs and removing the need to dilute samples in patients with established carcinoid disease being monitored for therapeutic efficacy. (C) 2010 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据