4.5 Article

Determination of glyphosate, glyphosate metabolites, and glufosinate in human serum by gas chromatography-mass spectrometry

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jchromb.2008.10.003

关键词

Glyphosate; Serum; Gas chromatography-mass spectrometry

向作者/读者索取更多资源

This paper describes an assay for the determination of glyphosate (GLYP), glyphosate metabolites [(aminomethyl) phosphonic acid] (AMPA), and glufosinate (GLUF) in human serum. After protein precipitation using acetonitrile and solid-phase extraction, serum samples were derivatized and analyzed by gas chromatography-mass spectrometry (GC-MS). The assay was linear over a concentration range of 3-100.0 mu g/ml for GLYP, AMPA, and GLUF. The overall recoveries for the three compounds were > 73%. The intra- and inter-day variations were < 15%. Precision and accuracy were 6.4-10.6% and 88.2-103.7%, respectively. The validated method was applied to quantify the GLYP and AMPA content in the serum of a GLYP-poisoned patient. in conclusion, the method was successfully applied for the determination of GLYP and its metabolite AMPA in serum obtained from patient of GLYP-poisoning. (c) 2008 Elsevier B.V. All rights reserved.