In this study, two materials are presented with strong cation-exchange (SCX) behaviour synthesised by two different approaches and then crushed for their application as sorbents for solid-phase extraction (SPE) to extract a group of pharmaceuticals and illicit drugs selectively from wastewater samples. The first SCX polymer was obtained by copolymerisation of three monomers: 2-acrylamido-2-methylpropane sulphonic acid (AMPSA), 2-hydroxyethyl methacrylate (HEMA) and pentaerythritol triacrylate (PETRA), while the second was obtained by post-modification with sulphuric acid (H2SO4) of a copolymer based on HEMA and divinylbenzene (DVB). After their syntheses, both polymers were evaluated as SPE sorbents, with all parameters affecting SPE being optimised, such as sample pH, washing and elution solvents and volumes. Thanks to the sulphonic groups present in the structure of the polymers, all of the compounds with basic functionalities were retained on the sorbents after the washing step, removing the acidic analytes and other interfering compounds, providing successful results in terms of ion suppression/enhancement (-12% and 21%) when wastewater samples were analysed. However, AMPSA/HEMA/PETRA (20/60/20) failed to retain the analytes after loading wastewater samples (25 or 50 mL), decreasing analyte recovery values significantly, whereas the sulphonated HEMA/DVB (50/50) enabled good SPE performance with recovery values between 70% and 98%, except for ranitidine and EDDP (39% and 43%, respectively). Therefore, this polymer was selected for further method validation and quantification of wastewater samples, providing low method detection limits (MDLs) in this matrix (from 2 to 40 ng L-1). Finally, most of the studied compounds were detected and quantified in wastewater samples, especially atenolol, ranitidine, cocaine and its metabolite benzoylecgonine. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据