4.6 Review

Bioanalytical chromatographic method validation according to current regulations, with a special focus on the non-well defined parameters limit of quantification, robustness and matrix effect

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1353, 期 -, 页码 10-27

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2014.03.077

关键词

Method validation; Bioanalysis; Limit of quantification; Robustness; Matrix effect

资金

  1. Ministry of Science and Education
  2. Basque Country Government
  3. University of Basque Country/EHU [CTQ09-1169, IT89-13, IT789-13, PPM12/06, UFI 11/23]
  4. SGIker

向作者/读者索取更多资源

Method validation is a mandatory step in bioanalysis, to evaluate the ability of developed methods in providing reliable results for their routine application. Even if some organisations have developed guidelines to define the different parameters to be included in method validation (FDA, EMA); there are still some ambiguous concepts in validation criteria and methodology that need to be clarified. The methodology to calculate fundamental parameters such as the limit of quantification has been defined in several ways without reaching a harmonised definition, which can lead to very different values depending on the applied criterion. Other parameters such as robustness or ruggedness are usually omitted and when defined there is not an established approach to evaluate them. Especially significant is the case of the matrix effect evaluation which is one of the most critical points to be studied in LC-MS methods but has been traditionally overlooked. Due to the increasing importance of bioanalysis this scenario is no longer acceptable and harmonised criteria involving all the concerned parties should be arisen. The objective of this review is thus to discuss and highlight several essential aspects of method validation, focused in bioanalysis. The overall validation process including common validation parameters (selectivity, linearity range, precision, accuracy, stability...) will be reviewed. Furthermore, the most controversial parameters (limit of quantification, robustness and matrix effect) will be carefully studied and the definitions and methodology proposed by the different regulatory bodies will be compared. This review aims to clarify the methodology to be followed in bioanalytical method validation, facilitating this time consuming step. (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据