4.6 Article

Evaluation and validation of an accurate mass screening method for the analysis of pesticides in fruits and vegetables using liquid chromatography-quadrupole-time of flight-mass spectrometry with automated detection

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1373, 期 -, 页码 40-50

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2014.10.099

关键词

Screening; Validation; LC-HRMS; Pesticides; Fruits and vegetables; QuEChERS

资金

  1. Spanish Ministry of Education, Culture and Sport

向作者/读者索取更多资源

This study reports the development and validation of a screening method for the detection of pesticides in 11 different fruit and vegetable commodities. The method was based on ultra performance liquid chromatography-quadrupole-time of flight-mass spectrometry (UPLC-QTOF-MS). The objective was to validate the method in accordance with the SANCO guidance document (12571/2013) on analytical quality control and validation procedures for pesticide residues analysis in food and feed. Samples were spiked with 199 pesticides, each at two different concentrations (0.01 and 0.05 mg kg(-1)) and extracted using the QuEChERS approach. Extracts were analysed by UPLC-QTOF-MS using generic acquisition parameters. Automated detection and data filtering were performed using the UNIFITM software and the peaks detected evaluated against a proprietary scientific library containing information for 504 pesticides. The results obtained using different data processing parameters were evaluated for 4378 pesticide/commodities combinations at 0.01 and 0.05 mg kg(-1). Using mass accuracy (+/- 5 ppm) with retention time (+/- 0.2 min) and a low response threshold (100 counts) the validated Screening Detection Limits (SDLs) were 0.01 mgkg(-1) and 0.05 mg kg(-1) for 57% and 79% of the compounds tested, respectively, with an average of 10 false detects per sample analysis. Excluding the most complex matrices (onion and leek) the detection rates increased to 69% and 87%, respectively. The use of additional parameters such as isotopic pattern and fragmentation information further reduced the number of false detects but compromised the detection rates, particularly at lower residue concentrations. The challenges associated with the validation and subsequent implementation of a pesticide multi-residue screening method are also discussed. Crown Copyright (C) 2014 Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据