4.6 Article

Magnetic nanoparticles based dispersive micro-solid-phase extraction as a novel technique for coextraction of acidic and basic drugs from biological fluids and waste water

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1338, 期 -, 页码 1-8

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2014.02.027

关键词

Dispersive micro-solid phase extraction; Coextraction; Cetyltrimethyl ammonium bromide-coated; Fe3O4@decanoic acid; Diclofenac; Diphenhydramine

向作者/读者索取更多资源

The coextraction of acidic and basic drugs from different samples is a considerable and disputable concept in sample preparation strategies. In this study, for the first time, simultaneous extraction of acidic and basic drugs with magnetic nanoparticles based dispersive micro-solid phase extraction followed by high performance liquid chromatography-ultraviolet detection was introduced. Cetyltrimethyl ammonium bromide-coated Fe3O4@decanoic acid as an efficient sorbent was successfully applied to adsorb diclofenac (DIC) as an acidic and diphenhydramine (DPH) as a basic model compound. First, appropriate amount of synthetic Fe3O4@decanoic acid nanoparticles was added to aqueous solution of drugs. After adjusting the pH of the solution, cetyltrimethyl ammonium bromide (CAB) was added to the mixture being stirred at a constant rate. After the adsorption of drugs and decantation of supernatant with a magnetic field, the sorbent was eluted with methanol by fierce vortex. The parameters affecting the extraction efficiency were optimized and obtained as: pH of the sample = 9, concentration of CTAB = 0.2 mmol L-1, amount of sorbent = 10 mg, extraction time = 5 min, no salt addition to sample, type and volume of the eluent = 50 111 methanol, and desorption time = 1 min. Under the optimum conditions detection limits and linear dynamic ranges were achieved in the range of 1.8-3.0, 5-1500 1 mu L-1 for DPH and 1.5-3.5, 5-1500 mu g L-1 for DIC, respectively. The percent of extraction recovery and relative standard deviations (n =5) were in the range of 47.3 - 60, 5.2 - 9.0 for DPH and 64 - 76.7, 5.1 - 5.8 for DIC, respectively. Ultimately, the applicability of the method was successfully confirmed by the extraction and determination of DIC and DPH in human urine, plasma and waste water samples in the range of microgram per liter and satisfactory results were obtained. (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据