4.6 Article

Magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes for the determination of phthalate monoesters in urine samples

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1286, 期 -, 页码 22-28

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2013.02.070

关键词

Magnetic carbon nanotubes (MCNTs); Magnetic solid-phase extraction (MSPE); Phthalate; Phthalate monoesters (PMEs); Biomarker; MSPE-GC MS

资金

  1. Tehran University of Medical Sciences (TUMS)
  2. Health Services grant [89-03-46-11394]

向作者/读者索取更多资源

In this study, magnetic carbon nanotubes (MCNTs) were prepared by assembling magnetic nanoparticles onto the acid-treated multiwall carbon nanotubes (MWCNTs). Due to their excellent adsorption capability, the MCNTs were used as adsorbent of magnetic solid-phase extraction (MSPE) to extract phthalate monoesters (PMEs), the main biomarkers of phthalate exposure, from human urine. By coupling MSPE with gas chromatography-mass spectrometry (GC-MS), a reliable, sensitive and cost-effective method for the simultaneous determination of five main PMEs including monomethyl phthalate (MMP), monoethyl phthalate (MEP), mono n-butyl phthalate (MBP), mono-(2-ethylhexyl) phthalate (MEHP) and monobenzyl phthalate (MBzP) was developed. The factors that could influence the extraction, including the amount of magnetic nanoparticles, pH of sample solution, extraction and desorption time, the amount of salt addition, the type and volume of desorption solvent were investigated in detail. Under optimized conditions, the LODs and LOQs achieved were in the range of 0.025-0.050 and 0.125-0.250 ng mL(-1) respectively. And calibration curves were linear (r(2) >= 0.992) over the concentration ranges from 0.250 to 250 ng mL(-1). In addition, a satisfying reproducibility was achieved by evaluating the intra- and inter-day precisions with relative standard deviations (RSDs) less than 11.2% and 11.4%, respectively. The recoveries of the five PMEs ranged from 92.6% to 98.8% with the RSDs less than 10.7%. Finally, the established MSPE-GC-MS method was successfully applied to determine PMEs in human urine samples. MMP, MEP, MBP and MEHP were detected in most of the samples with the median concentration of 8.46, 9.26, 13.60, and 5.95 ng mL(-1) respectively. MBzP was detected in 58.3% of the samples with the median concentration of 3.05 ng mL(-1). Taken together, the MSPE-GC-MS method developed in current study provides a new option for the determination of PMEs in human urine. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据