4.6 Article

Layer-by-layer assembly of polyelectrolyte and graphene oxide for open-tubular capillary electrochromatography

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1282, 期 -, 页码 95-101

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2013.01.055

关键词

Graphene oxide; Polyelectrolyte; Layer-by-layer; Stationary phase; Open-tubular electrochromatography

资金

  1. NSFC [20975090, 20975091]
  2. foundation of the Excellence Science and Technology Invention Team in Yangzhou University
  3. Priority Academic Program Development of Jiangsu Higher Education Institutions

向作者/读者索取更多资源

In this paper, open-tubular capillary column coated with graphene oxide (GO) was prepared through ionic adsorption of negatively charged GO nanosheets onto the capillary wall pre-modified with positively charged poly(poly(diallydimethylammonium chloride) chloride) (PDDA). Thus prepared coating was very stable and could endure over 200 separations. The electroosmotic flow (EOF) characteristics of bare fused silica capillary column, PDDA coated column, and GO-PDDA coated column (GO-PDDA@column) were investigated by varying the percentage of methanol in buffer and the buffer pH value. The run-to-run, day-to-day, and column-to-column reproducibilities of EOF on GO-PDDA@column were satisfying with relative standard deviation values of less than 2% in all cases. The stationary phase displays a characteristic reversed-phase behavior. The GO-PDDA@column was also used to separate proteins in egg white. Both basic and acidic proteins were separated in a single run. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据