4.6 Article

Analysis of preservatives with different polarities in beverage samples by dual-phase dual stir bar sorptive extraction combined with high-performance liquid chromatography

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1278, 期 -, 页码 8-15

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2012.12.061

关键词

Dual-phase dual stir bar sorptive extraction; High-performance liquid chromatography; Preservative; Beverage

资金

  1. National Nature Science Foundation of China [20775057]
  2. Science Fund for Creative Research Groups of NSFC [20621502, 20921062]
  3. Fundamental Research Funds for the Central Universities [114009]

向作者/读者索取更多资源

A new concept of dual-phase dual stir bar sorptive extraction (SBSE) was proposed to simultaneously extract six preservatives with different polarities (log Ko/w values of 1.27-3.41), namely, benzoic acid (BA), sorbic acid (SA), methyl p-hydroxybenzoate (MP), ethyl p-hydroxybenzoate (EP), propyl p-hydroxybenzoate (PP), and butyl p-hydroxybenzoate (BP). The dual-phase dual SBSE apparatus was consisted of two differently coated stir bars, a 3-aminopropyltriethoxysilane (APTES)-hydroxy-terminated silicone oil (OH-TSO)-coated stir bar that was prepared by sol-gel technique and a C-18 silica (C-18)-polydimethylsiloxane (PDMS)-coated stir bar that was prepared by adhesion. In dual-phase dual SBSE, the two stir bars with different coatings were placed in the same sample solution for the simultaneous extraction of the target analytes with different polarities, and then the bars were desorbed in the same desorption solvent. The extraction performance of the dual-phase dual SBSE for the six preservatives was evaluated by comparing with the conventional SBSE (individual stir bar) with different coatings, including commercial PDMS, homemade PDMS, C-18-APTES-OH-TSO, APTES-OH-TSO, and C-18-PDMS. The experimental results showed that the dual-phase dual SBSE had the highest extraction efficiency for the six target preservatives. Based on this fact, a novel method by combining the dual-phase dual SBSE which was consisted of the APTES-OH-TSO-coated and C-18-PDMS-coated stir bars with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was developed for the simultaneous analysis of six target beverage preservatives in beverages. Under optimal conditions, the limits of detection (LODs) for six target preservatives ranged from 0.6 to 2.7 mu g L-1 with the relative standard deviations (RSDs) of 4.6-9.2% (C-BA,C-SA = 5 mu g L-1, C-MP = 20 mu g L-1, C-EP,C-PP,C-BP = 10 mu g L-1, n = 7). The enrichment factors (EFs) were approximately 16-42-fold (theoretical EF was 50-fold). The proposed method was validated by the analysis of six target preservatives in three kinds of beverage samples, and the recoveries for the spiked samples were in the range of 76.6-118.6% for cola, 74.6-17.5% for orange juice, and 83.0-119.1% for herbal tea, respectively. (c) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据