4.6 Article

Determination of ochratoxins in nuts and grain samples by in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1220, 期 -, 页码 1-6

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2011.11.008

关键词

In-tube solid-phase microextraction; Automated sample preparation; Liquid chromatography-mass spectrometry; Ochratoxin; Mycotoxin; Nuts and grain samples

资金

  1. The Promotion and Mutual Aid Corporation for Private Schools of Japan
  2. The Science Research Promotion Fund
  3. [19590049]

向作者/读者索取更多资源

A simple and sensitive method for the determination of ochratoxins A and B in nuts and grain samples was developed using an automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-mass spectrometry (LC-MS). Ochratoxins were separated within 5 min by high-performance liquid chromatography using an Inertsil ODS-3 column with 5 mM anmonium acetate/acetonitrile (65/35, v/v) as the mobile phase. Electrospray ionization conditions in the positive ion mode were optimized for mass spectrometric detection of ochratoxins. The pseudo molecular ion [M+H](+) was used to detect ochratoxins with selected ion monitoring (SIM) mode. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 mu L of sample using a Carboxen-1006 PLOT capillary column as an extraction device. The extracted ochratoxins were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME/LC-MS with SIM method, good linearities of the calibration curves (r = 0.9993 for ochratoxin A and r = 0.9989 for ochratoxin B) were obtained in the concentration range from 0.5 to 20 ng/mL. The detection limits (S/N = 3) for ochratoxins A and B were 92 and 89 pg/mL, respectively. The in-tube SPME method showed above 15-19-fold greater sensitivity than the direct injection method (10 mu L injection). The within-clay and between-day precisions (relative standard deviations) were below 5.1% and 7.7% (n = 6), respectively. This method was applied successfully to analysis of nuts and grain samples without interference peaks. The recoveries of ochratoxins spiked into extraction solution from nut samples were above 88%. Ochratoxins were detected at 0.7-8.8 ng/g levels in various nuts and grain samples. (C) 2011 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据