Screening approaches adopted in pharmaceutical companies for chiral LC method development may be quite complicated and sophisticated in order to guarantee a high success rate. However in other environments it may be of more value to assess how simple a screen might be used to still have a good chance of achieving success. The genuine need to develop chiral separations for the former 'legal-high' drug mephedrone and related cathinones of topical interest presented a good opportunity to develop this theme. in initial work on mephedrone itself, no chiral separation was observed on Chirobiotic V. Cyclobond I 2000 DNP, Whelk-O1 and AmyCoat using reversed phase mobile phases. However, using normal phase solvents, chiral separation was observed on all the chiral stationary phases (CSP) used except Chiralcel DJ-H. Of the chiral separations observed on RegisPack, RegisCell and Whelk-O1, some optimisation work was carried out on the latter two which had showed the greatest enantioselectivity. Following optimisation, the best enantioselectivity (1.59) and enantioresolution (5.90) was found with a 250 mm x 4.6 mm I.D. Whelk-O1 column using a propan-2-ol (IPA)-hexane-trifluoroacetic acid (TFA)-triethylamine (TEA) (10:90:0.05:0.05, v/v/v/v) mobile phase. Subsequent screening on other cathinones was restricted to RegisPack, RegisCell and Whelk-O1 or equivalent phases with two mobile phases and this gave a very good success rate. Indeed it was possible to separate all six cathinones on one column, RegisCell, with one mobile phase. propan-2-ol-hexane-TFA (15:85:0.1, v/v/v) but obviously it had been necessary to go through the 3-column screen to arrive at this finding. While Whelk-O1 was not so successful, ease of optimisation on this phase was again a feature. To illustrate the applicability of these separations, it was shown that, as a basis for semi-preparative work, the optimsed mephedrone separation on Whelk-O1 could be scaled-up to a 2000 pi injection of a 1.0 mg ml(-1) solution in mobile phase (2.0 mg on-column) while still using the 250 mm x 4.6 mm I.D. analytical column. (C) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据