4.6 Article

Multi-residue analysis of drugs of abuse in wastewater and surface water by solid-phase extraction and liquid chromatography-positive electrospray ionisation tandem mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1218, 期 12, 页码 1620-1631

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2011.01.060

关键词

Illicit drugs; Drugs of abuse; Precursors; UPLC; Wastewater; Surface water; Environment; LC-MS/MS; Sewage; Crack cocaine; SPE; Pharmaceuticals; Multi-residue

资金

  1. University of Huddersfield

向作者/读者索取更多资源

A new-multi residue method was developed for the environmental monitoring of 65 stimulants, opiod and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, human urine indicators and their metabolites in wastewater and surface water. The proposed analytical methodology offers rapid analysis for a large number of compounds, with low limits of quantification and utilises only one solid-phase extraction-ultra performance liquid chromatography-positive electrospray ionisation tandem mass spectrometry (SPE-LC-MS/MS) method, thus overcoming the drawbacks of previously published procedures. The method employed solid phase extraction with the usage of Oasis MCX sorbent and subsequent ultra performance liquid chromatography-positive electrospray ionisation tandem mass spectrometry. The usage of a 1.7 mu m particle size column (1 mm x 150 mm) resulted in very low flow rates (0.04 mL min(-1)), and as a consequence gave good sensitivity, low mobile phase consumption and short retention times for all compounds (from 2.9 to 23.1 min). High SPE recoveries (>60%) were obtained for the majority of compounds. The mean correlation coefficients of the calibration curves were typically higher than 0.997 and showed good linearity in the range 0-1000 mu g L-1. The method limits of detection ranged from 0.1 ng L-1 for compounds including cocaine, benzoylecgonine, norbenzoylecgonine and 2-oxo-3-hydroxy-LSD to 100 ng L-1 for caffeine. Method quantification limits ranged from 0.5 to 154.2 ng L-1. Intra-and inter-day repeatabilities were on average less than 10%. The method accuracy range was within -33.1 to 30.1%. The new multi-residue method was used to analyse drugs of abuse in wastewater and river water in the UK environment. Of the targeted 65 compounds, 46 analytes were detected at levels above the method quantification limit (MQL) in wastewater treatment plant (WWTP) influent, 43 in WWTP effluent and 36 compounds in river water. (C) 2011 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据