4.6 Article

A novel reusable ionic liquid chemically bonded fused-silica fiber for headspace solid-phase microextraction/gas chromatography-flame ionization detection of methyl tert-butyl ether in a gasoline sample

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1218, 期 1, 页码 130-136

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2010.10.114

关键词

Ionic liquid; Chemically bonding; Solid-phase microextraction; Methyl tert-butyl ether; Gasoline sample; Gas chromatography

资金

  1. Research Council of K.N. Toosi University of Technology
  2. Research Council of Research Institute of Petroleum Industry
  3. Research Council of Iranian National Center for Oceanography

向作者/读者索取更多资源

A novel ionic liquid (IL) bonded fused-sil-ica fiber for headspace solid-phase microextraction (HS-SPME)/gas chromatography-flame ionization detection (GC-FID) of methyl tert-butyl ether (MTBE) in a gasoline sample was prepared and used. The new proposed chemically bonded fiber has better thermal stability and durability than its corresponding physically coated fiber. Another advantage is that no spacer was used for the purpose of bonding the IL to the surface of the fused-silica. The latter advantage makes the preparation of these fibers easier with lower cost than those prepared using sol-gel method. The ionic liquid 1-methyl-3-(3-trimethoxysilyl propyl) imidazolium bis(trifluoromethylsulfonyl) imide was synthesized and cross linked to the surface of the fused-silica fiber. Then, the chemically IL-modified fibers were applied to the headspace extraction of MTBE. The chemically IL-modified fibers showed improved thermal stability at temperatures up to 220 degrees C relative to the physically IL-modified fibers (180 degrees C). The chemically bonded IL film on the surface of the fused-silica fiber was durable over 16 headspace extractions without any significant loss of the IL film. The calibration graph was linear in a concentration range of 2-240 mu g L-1 (R-2 = 0.996) with the detection limit of 0.1 mu g L-1 level. The reproducibility (RSD %, n = 6) of the new IL bonded fused-silica fiber (8.9%) was better than the physically coated fiber (12%) suggesting that the proposed chemically IL-modified fiber is more robust than the physically IL-modified fiber. The optimum extraction conditions were the followings: 40 degrees C extraction temperature, 12 min extraction time, 30s desorption time and sample agitation at 200 rpm. (C) 2010 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据