4.6 Article

Sensitive determination of phenylarsenic compounds based on a dual preconcentration method with capillary electrophoresis/UV detection

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1218, 期 29, 页码 4779-4787

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2011.05.058

关键词

Hollow fiber liquid liquid liquid microextraction; Anion selective exhaustive injection; Phenylarsenic compounds; Capillary electrophoresis; Pig feed

资金

  1. NSFC [20621502, 20921062]
  2. National Nature Science Foundation of China [20775057]
  3. MOE of China [NCET-04-0658]

向作者/读者索取更多资源

A novel method based on off-line hollow fiber based liquid liquid liquid microextraction (HF-LLLME) combined with on-column anion selective exhaustive injection (ASEI)-capillary electrophoresis/ultraviolet (CE/UV) detection was proposed for the speciation of five phenylarsenic compounds including phenylarsonic acid (PM), 4-aminophenylarsonic acid (4-APAA), 4-hydroxyphenylarsonic acid (4-HPAA), 4-nitrophenylarsonic acid (4-NPAA) and 3-nitro-4-hydroxyphenylarsonic acid (NHPAA) in this paper. In HF-LLLME, the target analytes were extracted from 5 mL aqueous samples (donor solution pH 2.15) through a thin phase of tributyl phosphate (TBP) inside the pores of a polypropylene hollow fiber and finally into an 18 mu L 0.8 mmol/L Tris acceptor solution inside the lumen of the hollow fiber. Following HF-LLLME, the acceptor solutions were directly analyzed by ASEI-CE/UV. For ASEI, a large plug of water (91% length of total capillary) was introduced into the separation capillary before sample injection in order to prolong the sample injection time, and thus enhance the stacking efficiency. Under the optimized ASEI conditions, up to 236-fold of enrichment factor (EF) was obtained for the ASEI-CE/UV determination of target phenylarsenic compounds. By combining HF-LLLME with ASEI-CE/UV, EFs ranging from 155 to 1780-fold were achieved and the limits of detection (LODs) (at a signal-to-noise ratio of 3) were in the range of 0.68-6.90 mu g/L for five phenylarsenic compounds; the relative standard deviations (RSDs) of corrected peak area were 5.6-11.8%. The proposed HF-LLLME-ASEI-CE/UV method was applied for the determination of five target phenylarsenic compounds in pig feed from a local pig farm, and storage pig litter, soil in agricultural field and lake water collected near this pig farm, the recoveries for the spiked samples were in the range of 85.7-104.5%, 66.7-96.2%, 28.9-46.9% and 86.9-107.8% for pig feed, pig litter, soil and lake water, respectively. (C) 2011 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据