4.6 Article

Supramolecular solvents in solid sample microextractions: Application to the determination of residues of oxolinic acid and flumequine in fish and shellfish

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1217, 期 9, 页码 1447-1454

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2009.12.073

关键词

Microextraction; Supramolecular solvent; Quinolone antibiotics; Fish; Shellfish; Liquid chromatography/fluorescence detection

资金

  1. Spanish MICINN [CTQ2008-01068]
  2. Andalusian CICyE

向作者/读者索取更多资源

Supramolecular solvents are here proposed firstly as extractants in solid sample microextractions. The approach was evaluated by extracting flumequine (FLU) and oxolinic acid (OXO), two widely used veterinary medicines, from fish and shellfish muscle using a supramolecular solvent made up of decanoic acid (DeA) reverse micelles. The antibiotics were extracted in a single step (similar to 15 min), at room temperature, using 400 mu L of solvent. After centrifugation, an aliquot of the extract was directly analyzed by liquid chromatography and fluorescence, without the need of clean-up or solvent evaporation. Contrary to the previously reported methods, both OXO and FLU were quantitatively extracted from fish and shellfish, independently of sample composition. The high extraction efficiencies observed for these antibiotics were a consequence of their amphiphilic character which resulted in the formation of DeA-OXO and DeA-FLU mixed aggregates. The quality parameters of this quantitative method including sensitivity, linearity, selectivity, repeatability, trueness, ruggedness, stability, decision limit and detection capability were evaluated according to the 2002/657/EC Commission Decision. Quantitation limits in the different samples analyzed (salmon, sea trout, sea bass, gilt-head bream, megrim and prawns) ranged between 6.5 and 22 mu g kg(-1) for OXO and, 5 and 15 mu g kg(-1) for FLU. These limits were far below the current maximum residue limits (MRLs) set by the European Union (EU) (i.e. 100 and 600 mu g kg(-1), for OXO and FLU, respectively). The trueness of the method was determined by analyzing a Certified Reference Material (CMR. BCR (R)-725) consisting of a lyophilised salmon tissue material. Recoveries for fortified samples (50-100 mu g kg(-1) of OXO and 50-600 mu g kg(-1) of FLU) and their relative standard deviations were in the intervals 99-102% and 0.2-5%, respectively. The repeatability, expressed as relative standard deviation, was 3.6% for OXO and 2.3% for FLU ([OXO] = [FLU] = 200 mu g kg(-1) and n = 11). (C) 2009 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据