4.6 Article

Simple approach based on ultrasound-assisted emulsification-microextraction for determination of polibrominated flame retardants in water samples by gas chromatography-mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1216, 期 1, 页码 147-153

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2008.11.034

关键词

Polybrominated diphenyl ethers; Brominated name retardants; Ultrasound-assisted emulsification-microextraction; Water analysis; Gas Chromatography-mass spectrometry

资金

  1. Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET)
  2. Agencia Nacional de Promocion Cientifica y Tecnologica (FONCYT) (PICT-BID)
  3. Universidad Nacional de San Luis, Argentina

向作者/读者索取更多资源

simple, efficient, innovative and environmentally friendly analytical technique Was Successfully applied for the first time for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) from water samples. The PBDEs selected for this work were those most commonly found in the literature in natural water samples: 2,2',4,4'-tetraBDE (BDE-47), 2.2'.4,4,5-pentaBDE (BDE-99), 2,2',4,4,6-pentaBDE (BDE-100) and 2,2,4,4',5.5'-hexaBDE (BDE-153). The extracted PBDEs were separated and determined by gas chromatography-mass spectrometry(CC-MS). The extraction/preconcentration technique is based on Ultrasound-assisted emulsification-microextraction (USAEME) of a water-immiscible solvent in an aqueous medium. Several variables including. solvent type, extraction time, extraction temperature and matrix modifiers were studied and optimized over the relative response the target analytes. Chloroform Was used as extraction solvent in the USAEME technique. Under optimum conditions, the target analytes were quantitatively extracted achieving enrichment factors (EF) higher than 319. The detection limits (LODs) of the analytes for the preconcentration of 10 mL sample volume were within the range 1-2 pg mL(-1). The relative standard deviations (RSD) for five replicates at 10 pg mL(-1) concentration level were < 10.3%. The calibration graphs were linear within the concentration range of 5-5000 pg mL(-1) for BDE-47 and BDE-100; and 5-10,000 pg mL(-1) for BDE-99 and BDE-153, respectively. The coefficients of estimation were >0.9985. Validation of the methodology was performed by standard addition method at two concentration levels (10 and 50 pg mL(-1)). Recovery values were >96%, which showed a successful robustness of the analytical methodology for determination of picogram per milliliter of PBDEs in water samples. Significant quantities of PBDEs were not found in the analyzed samples. (C) 2008 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据