4.6 Article

Ultrasound-assisted dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-fluorescence detection for sensitive determination of biogenic amines in rice wine samples

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1216, 期 38, 页码 6636-6641

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2009.07.070

关键词

Ultrasound-assisted dispersive liquid-liquid microextraction; Biogenic amines; 2,6-Dimethyl-4-quinolinecarboxylic acid; N-hydroxysuccinimide ester; High-performance liquid chromatography-fluorescence detection; Rice wine samples

资金

  1. National Natural Science Foundation of China [20805040, 20875080]
  2. Natural Science Foundation of He'nan Province of China [082300420140]
  3. Foundation of He'nan Educational Committee [2008A150020]
  4. Excellent Youth Foundation of He'nan Scientific Committee [084100410024]
  5. Program for Science & Technology Innovation Talents in Universities of Henan Province [2010HASTIT025]

向作者/读者索取更多资源

Ultrasound-assisted dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-fluorescence detection was used for the extraction and determination of three biogenic amines including octopamine. tyramine and phenethylamine in rice wine samples. Fluorescence probe 2.6-dimethyl-4-quinolinecarboxylic acid N-hydroxysuccinimide ester was applied for derivatization of biogenic amines. Acetonitrile and 1-octanol were used as disperser solvent and extraction solvent, respectively. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, ultrasonication time and centrifuging time were optimized. After extraction and centrifuging, analyte was injected rapidly into high-performance liquid chromatography and then detected with fluorescence. The calibration graph of the proposed method was linear in the range of 5-500 mu g mL(-1) (octopamine and tyramine) and 0.025-2.5 mu g mL(-1) (phenethylamine). The relative standard deviations were 2.4-3.2% (n = 6) and the limits of detection were in the range of 0.02-5 ng mL(-1). The method was applied to analyze the rice wine samples and spiked recoveries in the range of 95.42-104.56% were obtained. The results showed that ultrasound-assisted dispersive liquid-liquid microextraction was a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of biogenic amines. (C) 2009 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据