4.6 Article

Development and validation of a normal-phase high-performance thin layer chromatographic method for the analysis of sulfamethoxazole and trimethoprim in co-trimoxazole tablets

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1216, 期 42, 页码 7102-7107

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2009.08.076

关键词

Method development; Method validation; Normal-phase HPTLC; Sulfamethoxazole (SMX); Trimethoprim (TMP); Co-trimoxazole tablets

资金

  1. Belgium Technical Cooperation (BTC)
  2. Fund for Scientific Research (FWO-Flanders)

向作者/读者索取更多资源

Pneumocystis carinii pneumonia (PCP) is often the ultimate mortal cause for immunocompromised individuals, such as HIV/AIDS patients. Currently, the most effective medicine for treatment and prophylaxis is co-trimoxazole, a synergistic combination of sulfamethoxazole (SMX) and trimethoprim (TMP). In order to ensure a continued availability of high quality co-trimoxazole tablets within resource-limited countries, Medicines Regulatory Authorities must perform quality control of these products. However, most pharmacopoeial methods are based on high-performance liquid chromatographic (HPLC) methods. Because of the lack of equipment, the Tanzania Food and Drugs Authority (TFDA) laboratory decided to develop and validate an alternative method of analysis based on the TLC technique with densitometric detection, for the routine quality control of co-trimoxazole tablets. SMX and TMP were separated on glass-backed silica gel 60 F-254 plates in a high-performance thin layer chromatograph (HPTLC). The mobile phase was comprised of toluene, ethylacetate and methanol (50:28.5:21.5, v:v:v). Detection wavelength was 254 nm. The R-f values were 0.30 and 0.61 for TMP and SMX, respectively. This method was validated for linearity, precision, trueness, specificity and robustness. Cochran's criterion test indicated homoscedasticity of variances for the calibration data. The F-tests for lack-of-fit indicated that straight lines were adequate to describe the relationship between spot areas and concentrations for each compound. The percentage relative standard deviations for repeatability and time-different precisions were 0.98 and 1.32, and 0.83 and 1.64 for SMX and TMP, respectively. Percentage recovery values were 99.00% +/- 1.83 and 99.66% +/- 1.21 for SMX and TMP, respectively. The method was found to be robust and was then successfully applied to analyze co-trimoxazole tablet samples. (C) 2009 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据