期刊
JOURNAL OF CHEMICAL AND ENGINEERING DATA
卷 55, 期 10, 页码 4168-4175出版社
AMER CHEMICAL SOC
DOI: 10.1021/je100198g
关键词
-
资金
- Royal Society
- Shell International Exploration and Production B.V.
Interfacial tension measurements are reported for the (H2O + CO2) system at pressures of (1 to 60) MPa and temperatures of (298 to 374) K. The pendant drop method was implemented using a high-pressure apparatus consisting of a view cell, fitted with a high-pressure capillary tube for creating pendant H2O drops in the CO2 bulk phase. The reported results have a relative standard deviation in most cases of less than 1.0 % and are in good agreement with literature values at low pressures. However, at higher pressures (up to 45 MPa), there is a significant scatter in the published data; the reasons for this are discussed. Measurements in the present work extend the pressure range or available data tip to pressures of 60 MPa.