期刊
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY
卷 22, 期 3, 页码 346-349出版社
WILEY
DOI: 10.1111/j.1540-8167.2010.01847.x
关键词
Ablation; fluoroscopy; pregnancy; intracardiac echocardiography
资金
- St. Jude Medical
- Boston Scientific
Methods and Results: A 20-year-old woman, 27 weeks pregnant, was admitted with congestive cardiac failure and incessant atrial tachycardia. She had an elevated brain natriuretic peptide (BNP) and chest X-ray demonstrating heart failure. The 12-lead electrocardiogram (ECG) showed atrial tachycardia with a cycle length of 310 ms, inverted P waves in lead I and the inferior leads, and a ventricular rate of 84 bpm during 2:1 block. Echocardiogram showed a global reduction in left ventricular function with a left ventricular ejection fraction (LVEF) of 0.40. Electrical cardioversion failed. Rate control could not be achieved with beta-blockers and calcium antagonists. Amiodarone with repeat cardioversion was also unsuccessful. The patient then underwent catheter ablation. The entire procedure was performed using intracardiac echocardiography (ICE) and electroanatomical mapping with no fluoroscopy. Electrophysiology (EP) study and an activation map of the left atrium confirmed a focal left atrial tachycardia which was successfully ablated. Six weeks postablation, the left ventricular function had normalized and the patient delivered a healthy child at term, without complication. Conclusion: Ablation of left atrial tachycardia using ICE and electroanatomical guidance is feasible in pregnant women. (J Cardiovasc Electrophysiol, Vol. 22, pp. 346-349, March 2011).
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐