Association Between Global Biomarkers of Oxidative Stress and Hip Fracture in Postmenopausal Women: A Prospective Study

期刊

JOURNAL OF BONE AND MINERAL RESEARCH
卷 29, 期 12, 页码 2577-2583

出版社

WILEY
DOI: 10.1002/jbmr.2302

关键词

FLUORESCENT OXIDATION PRODUCTS; OXIDATIVE STRESS; HIP FRACTURE; POSTMENOPAUSAL WOMEN

资金

  1. Dr. Wu's American Heart Association [0430202N]
  2. K07 award [CA138714]
  3. National Institute of Health, Bethesda, MD [HL34594, CA49449, CA131218, CA87969]
  4. [P30-ES006096]

向作者/读者索取更多资源

Human studies suggest that oxidative stress is a risk factor for osteoporosis, but its relationship with fracture risk is poorly understood. The purpose of the present study was to investigate the association between biomarkers of oxidative stress and hip fracture in postmenopausal women. We conducted a prospective study in the Nurses' Health Study among 996 women aged 60 years or older at baseline blood collection in 1989-1990. Plasma fluorescent oxidation products (FlOPs) were measured at three excitation/emission wavelengths (360/420nm named as FlOP_360; 320/420nm named as FlOP_320; and 400/475nm named as FlOP_400). FlOPs are generated from many different pathways (lipid, protein, and DNA) and reflect a global oxidation burden. FlOP assay is 10-100 times more sensitive than measurement of malondialdehyde. We used Cox proportional hazards regression model to investigate the association between baseline plasma FlOPs and the risk of hip fracture, adjusting for multiple hip fracture risk factors such as age, history of osteoporosis, history of hypertension, prior fracture, and smoking status. Forty-four hip fractures (4.4%) were identified during the follow-up (maximum=23 years). In the multivariable model, the hazard ratios (HRs) of hip fracture in the second and third tertiles of FlOP_320 were 2.11 (95% confidence interval [CI]=0.88-5.10) and 2.67 (95% CI=1.14-6.27), respectively, in comparison with the lowest tertile, and the risk increased linearly with increasing FlOP_320 (p for trend=0.021). Neither FlOP_360 nor FlOP_400 was significantly associated with risk of hip fracture (tertile 3 versus tertile 1: HR=0.70, 95% CI=0.32-1.54, p for trend=0.386 for FlOP_360; and HR=0.88, 95% CI=0.40-1.96, p for trend=0.900 for FlOP_400). In this prospective study, higher plasma FlOP_320 was an independent risk factor for hip fracture. Our results need further confirmation. (c) 2014 American Society for Bone and Mineral Research.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据