4.6 Article

Independent Clinical Validation of a Canadian FRAX Tool: Fracture Prediction and Model Calibration

期刊

JOURNAL OF BONE AND MINERAL RESEARCH
卷 25, 期 11, 页码 2350-2358

出版社

WILEY-BLACKWELL
DOI: 10.1002/jbmr.123

关键词

BONE MINERAL DENSITY; DUAL X RAY; ABSORPTIOMETRY; OSTEOPOROSIS; FRACTURES; FRAX; ADMINISTRATIVE DATA; HISTORICAL COHORT STUDY

向作者/读者索取更多资源

A FRAX model for Canada was constructed for prediction of osteoporotic and hip fracture risk using national hip fracture data with and without the use of femoral neck bone mineral density (BMD) Performance of this system was assessed independently in a large clinical cohort of 36 730 women and 2873 men from the Manitoba Bone Density Program database that tracks all clinical dual-energy X ray absorptiometry (DXA) test results for the Province of Manitoba, Canada Linkage with other provincial health databases allowed for the direct comparison of fracture risk estimates from the Canadian FRAX model with observed fracture rates to 10 years (549 individuals with incident hip fractures and 2543 with incident osteoporotic fractures) The 10 year Kaplan-Meier estimate for hip fractures in women was 2 7% [95% confidence interval (CI) 2 1-34%] with a predicted value of 2 8% for FRAX with BMD and in men the observed risk was 3 5% (95% CI 0 8-6 2%) with predicted value of 29% The 10 year estimate of osteoporotic fracture risk for all women was 12 0% (95% CI 10 813 4%) with a predicted value of 111% for FRAX with BMD and in men the observed risk was 10 7% (95% CI 6 6-14 9%) with a predicted value of 8 4% Discrepancies were observed within some subgroups but generally were small Fracture discrimination based on receiver operating characteristic curve analysis was comparable with published meta analyses with area under the curve for osteoporotic fracture prediction of 0 694 (95% CI 0684-0 705) for FRAX with BMD and for hip fractures 0 830 (95% CI 0 815-0 846), both of which were better than FRAX without BMD or BMD alone Individual risk factors considered by FRAX made significant independent contributions to fracture prediction in one or more of the models In conclusion a Canadian FRAX tool calibrated on national hip fracture data generates fracture risk predictions that generally are consistent with observed fracture rates across a wide range of risk categories (C) 2010 American Society for Bone and Mineral Research

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据